Difference between revisions of "Low-pass filter"
(→Simulation mit TARGET 3001!) |
(→Spannungsvergleich bei bestimmter Frequenz) |
||
Line 27: | Line 27: | ||
= Simulation in TARGET 3001! = | = Simulation in TARGET 3001! = | ||
To start a simulation of a circuit in TARGET 3001! press the function key [F9].<br> | To start a simulation of a circuit in TARGET 3001! press the function key [F9].<br> | ||
− | == | + | == Voltage comparison at a certain frequency == |
− | + | To compare the input voltage Uin and the outpu voltage Uout at a certain frequency; fullfill the following steps:<br> | |
− | * | + | *After opening the simulation window with the function key [F9]; select the tab <b>Standard</b>. |
*Mit einem Klick auf <b>Erweiterte Einstellungen für die Transientenanalyse</b> können Sie die Simulation Ihren Anforderungen anpassen.<br> | *Mit einem Klick auf <b>Erweiterte Einstellungen für die Transientenanalyse</b> können Sie die Simulation Ihren Anforderungen anpassen.<br> | ||
*Durch Betätigen des <b>Auswahl ändern</b>-Buttons können Sie die zu simulierenden Spannungen und Ströme auswählen.<br> | *Durch Betätigen des <b>Auswahl ändern</b>-Buttons können Sie die zu simulierenden Spannungen und Ströme auswählen.<br> | ||
*Drücken Sie nun im Simulations-Fenster auf den Button <b>Simulation starten</b>.<br> | *Drücken Sie nun im Simulations-Fenster auf den Button <b>Simulation starten</b>.<br> | ||
− | *Jetzt sollte sich das Fenster mit der vollständigen Simulation in Form eines virtuellen Oszilloskops öffnen (s. | + | *Jetzt sollte sich das Fenster mit der vollständigen Simulation in Form eines virtuellen Oszilloskops öffnen (s. Picture3).<br><br> |
− | [[image:Verhältnis UaUe bei 5kHz.jpg|Simulation | + | [[image:Verhältnis UaUe bei 5kHz.jpg|Simulation of the input voltage Uin and the output voltage Uout at a certain frequency (5kHz)|750px]]<br> |
− | + | Picture3: Simulation of the input voltage Uin and the output voltage Uout at a certain frequency (5kHz)<br><br><br> | |
Sie sehen nun in Bild3 die Simulation der Schaltung aus Bild1. Zu Beginn kann der Grafik ein Einschwingvorgang entnommen werden. Die Amplitude der Ausgangsspannung Uout entspricht bei 5kHz circa 30% der Amplitude der Eingangsspannungs Uin. Dies kann auch mithilfe von Bild4 überprüft werden.<br><br><br> | Sie sehen nun in Bild3 die Simulation der Schaltung aus Bild1. Zu Beginn kann der Grafik ein Einschwingvorgang entnommen werden. Die Amplitude der Ausgangsspannung Uout entspricht bei 5kHz circa 30% der Amplitude der Eingangsspannungs Uin. Dies kann auch mithilfe von Bild4 überprüft werden.<br><br><br> | ||
Revision as of 11:45, 21 October 2015
Contents
Low-pass filter
The RC low-pass filter is an electronic circuit that filters the incoming Signal. Frequencies lower than the cutoff Freqquency pass the low-pass filter nearly unhindered and frequencies higher than the cutoff frequency are attenuated by the filter. The cutoff frequency depends on the used components of the circuit.
RC low-pass filter
The RC low-pass filter consists out of a resistor (R) in series with a capacitor (C) (s. Picture1).
Picture1: RC low-passfilter created with TARGET 3001!
You can open the circuit in TARGET 3001! with the name Sim-edu-RC-lowpass.t3001 in the Demo-Projects and directly start the simulation in the demoversion Discover for free. |
RL low-pass filter
Der RL low-pass filter consists out of a inductor (L) in series with a resistor (R) (s. Picture2).
RL low-pass filter
Picture2: RL low-pass filter created with TARGET 3001!
SYou can open the circuit in TARGET 3001! with the name Sim-RL-lowpass.t3001 in the Demo-Projects and directly start the simulation in the demoversion Discover for free. |
Simulation in TARGET 3001!
To start a simulation of a circuit in TARGET 3001! press the function key [F9].
Voltage comparison at a certain frequency
To compare the input voltage Uin and the outpu voltage Uout at a certain frequency; fullfill the following steps:
- After opening the simulation window with the function key [F9]; select the tab Standard.
- Mit einem Klick auf Erweiterte Einstellungen für die Transientenanalyse können Sie die Simulation Ihren Anforderungen anpassen.
- Durch Betätigen des Auswahl ändern-Buttons können Sie die zu simulierenden Spannungen und Ströme auswählen.
- Drücken Sie nun im Simulations-Fenster auf den Button Simulation starten.
- Jetzt sollte sich das Fenster mit der vollständigen Simulation in Form eines virtuellen Oszilloskops öffnen (s. Picture3).
750px
Picture3: Simulation of the input voltage Uin and the output voltage Uout at a certain frequency (5kHz)
Sie sehen nun in Bild3 die Simulation der Schaltung aus Bild1. Zu Beginn kann der Grafik ein Einschwingvorgang entnommen werden. Die Amplitude der Ausgangsspannung Uout entspricht bei 5kHz circa 30% der Amplitude der Eingangsspannungs Uin. Dies kann auch mithilfe von Bild4 überprüft werden.
Spannungsverhältnis in einem Frequenzbereich
Möchten Sie nun die Beziehung zwischen Eingangsspannung Uin und Ausgangsspannung Uout in einem bestimmten Frequenzspektrum betrachten, führen Sie folgende Schritte aus:
- Nachdem sie mit F9 das Simulationsfenster geöffnet haben, setzen Sie unter dem Tab Erweitert bei AC-Analysis sowie Probe (Save) ein Häkchen.
- Mit einem Doppelklick auf AC-Analysis können Sie den Frequenzbereich festlegen.
- Mit einem Doppelklick auf Probe (Save) können Sie die zu simulierenden Spannungen und Ströme auswählen.
- Drücken Sie auf den Button Target.Cir erzeugen und anschließend auf Simulation starten.
- Jetzt sollte sich das Fenster mit der vollständigen Simulation in Form eines virtuellen Oszilloskops öffnen.
- Um die Simulation anschaulicher zu gestalten, wählen Sie in dem virtuellen Oszilloskop unter dem Menüpunkt Ansicht die Option X - Achse logarithmisch aus.
Simulation Verhältnis der Eingangsspannung Uin und Ausgangsspannung Uout im Frequenzbereich von 100Hz bis 100kHz
Bild4: Simulation Verhältnis der Eingangsspannung Uin und Ausgangsspannung Uout im Frequenzbereich von 100Hz bis 100kHz